ECG/TEMP/NIBP/SpO2/RESP/PR multi-parameter patient monitor M8
Brief introduction:
Patient monitor is a kind of instrument or system which is used to measure and control
patients physiological parameters, which can be compared with known settings, if they
are higher than know settings, the system will alarm.
Features:
• 6 Standard parameters: ECG, TEMP, NIBP, SpO2, RESP, PR
• 8 inch high resolution color screen
• Real time S-T segment analysis, pace-maker detection
• Indication of incorrect manipulation and malfunction analysis
• Patient info input management function
• Large volume of tabular and praphic trends information storage and easy to recall
• Capture 2-hour dynamic trend
• Various interfaces:standard screen,trend screen,oxyCRG screen,big front screen
• Up to 400 groups NIBP list,60 alarm event records recall, 7-day trend chart in storage.
• Up to 2 hours working capacity of built-in rechargeable
lithium battery
• Unique accessory management cabinet
• Networking capacity
• ETCO2, cart, wall shelf are optional
Parameters:
ECG
|
Lead Mode 3-lead and 5-lead are optional Lead Selection I, II, III, avR, avL, avF, V Wave 5-lead: 2 channels 3-lead: 1channel Gain ×2.5mm/mV, ×5.0mm/mV, ×10mm/mV, ×20mm/mV HR Measuring and Alarm Range Range 15 ~ 300 bpm Accuracy ±1% or ±1bpm, which is greater Alarm Accuracy ±2bpm Resolution 1 bpm |
ST Segment Monitoring | Measuring and Alarm Range -0.6 mV~ + 0.8 mV |
Alarm | Available |
Review | Available |
Scan Speed for ECG Waveform is adjustable |
12.5mm/s accuracy ±10% 25mm/s accuracy±10% 50mm/s accuracy±10% |
Respiration
|
Method R-F(RA-LL) Impedance Differential Input Impedance >2.5 MΩ Measuring Impedance Range 0.3~5.0Ω Baseline Impedance Range 100Ω– 2500Ω Bandwidth 0.3 ~ 2.5 Hz |
Resp. Rate
|
Measuring and Alarm Range 0~120rpm Resolution 1 rpm Measuring Accuracy ±2 rpm Alarm Accuracy ±3rpm Apnea Alarm 10 ~ 40 S |
NIBP |
Method Oscillometry Mode Manual, Auto, continuous Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 / 90/120/240/480/960 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10~270mmHg Alarm Type SYS, DIA, MEAN |
Resolution
|
Pressure 1mmHg Cuff Pressure ±3 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg |
SpO2 |
Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2% 0% ~ 69% unspecified |
Pulse Rate(PR)
|
Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm |
TEMP |
Channel dual-channel Measuring and Alarm Range 0 ~ 50°C Resolution 0.1°C Accuracy ±0.1°C Actualization Interval about 1 Sec. Average Time Constant < 10 Sec. Alarm responding Time ≤2min |
Packaging Details: |
Packing: 1 unit/carton 1* Patient monitor reusable Spo2 sensor (1 pc); ECG cable and leadwire (1 pc); NIBP cuff and tube (1 pc); Built-in lithium battery (1 pc) 1*English user manual (1pc) |
Delivery Detail: | Shipped in 7 days after payment |
Competitive Advantage:
Biggest manufacturer in China
In stock supplies
1 year Warranty
100% quality guarante before shipment out
Nice after-sale service
Product Dimension | 33.00 x 33.00 x 20.00 cm |
Net Weight | 10.00 kg |
Gross Weight | 14.00 kg |
Packaging Size | 42.00 x 42.00 x 26.00 cm |
Export Carton | 1 PCS |
20FT | 900 PCS |
40FT | 1200 PCS |
40HQ | 1500 PCS |
Power Plug Standard | USA |
The core components | standard |
Standard Accessories | standard |